Model Number |
k603 |
|
NAME : Ion cleanse device MODEL: k- 603 ID NET WEIGHT: 2.5KG PACKING DIMENSION: 41CM * 29CM * 15.5CM (L*W*H) PRODUCT DIMENSION: 23CM * 20.5CM * 8CM (L*W*H) OUTER PACKING DIMENSION: 65CM * 43CM * 33.5CM VOLTAGE: 110V/220V RATED POWER: 60W CURRENT: 0.5�2.5A PACKING TERM:INNER PACKING:ALUMINIUM BOX OUTER PACKING:CARTON |
A、Products principle Water is resolved into a large amount of energy ion through ion cleanse device (positive and negative), make internal cell vigor strengthen, promote various enzymes live. Improve the human body organ circulating function., accelerate metabolism, make the human body get well gradually. Through the color that demonstrates, you can understand one's own health . B、Products function
- Improve arranging poisonous ability oneself of the body;
- Relieve the burden of the body organ ;
- Promote metabolism and blood circulation;
- Increase the vigor of cells;
- Iimprove the sleep effectively
C、Operation 1、before starts, The power line, Pole plate , the wrist belt plug separately inserts the host machine planting ,then Puts the pole plate in the washbasin ,puts on the wrist belt, then turns on the power source 2、turns on the power switch, the screen demonstration is as follows Enter Time 10�30
Time=30 V2.0 :According to (+) on key, (-) under key or use numeric keyboard input time, time is 30Minutes. After the input time presses down (ENT) button, then works.The time operation is as follows Time=06:28 pos+ T=30 M=3 E=1.5 Time=06:28 used time, pos+ ion pole,pos+ positive pole ,pos- Negative pole; T=30 time set,M=3 third model, E=1.5 current power,When the operating time achieves the hypothesis time, instrument automatic knock off, end of job.
- Then operation, may work under 1,2,3,model, the energy content respectively is 1.6? 1.8? 2.0. The when machine starts operation, it automatic select third pattern, the customer may choose the different pattern through �-� �+� the key. Presses down (ESC) ,will withdraws from the current operation, the machine constantly works under the corresponding energy content .The customer may act according to different local the water quality, puts in the suitable salt to adjust the work the strong and the weak .When presses down (ESC) key withdraws from the record condition, returns to wait for the condition.
4、This product is the third generation product, has the recorded time and the number of times function, When the customer needs to examine record, simultaneously presses down (1) the numeric keyboard, (ENT) the key turns on the power source, this time the screen demonstrated: 00298 Mins 93Time upline of demonstration total operating time, the downline of demonstration is total numbers .When The instrument work time achieve 10 minutes, namely show a time of record, when presses down (ESC) the key withdraws from the record condition, returns to the waiting status .
5、Users may input password, simultaneously eliminates already the number of times and the time which records .When operates the power source, simultaneously presses down(2 _) the numeric keyboard and (ENT) the key confirmed that, this time the screen reveals PAS:V2.0 Clear Contents This time may input 6 figures password , Then presses down (ENT) the key ,eliminated already records, When password mistake, the system restores to the start position, when password correct ,system demonstration following _ Process:OK Mins=00000 The demonstration operates successfully, presses down (ESC) the key then to return to the start position, When the instrument leaves the plant ,the password is �666666�
6、The user also may own revise the password, when must revise the password, turns on the power source simultaneously to press down (3) the numeric keyboard and (ENT) the key, by now screen demonstration as follows:PAS:V2.0 Change Password First must input the original 6 passwords, after the password input is correct, press (ENT) the key, this time the screen reveals : Process:OK New PAS:123456 Simultaneously demonstrated new password, after inputs finished ,pressing (ESC), withdrawal revision password condition, returns to the waiting status
- Then machines work, in case to the below situation, will prompt the sound and the character and visual display alarm
a)The pole plate puts out or the pole plate in the water appears breakdown N b)The wrist belt has not wraped in the skill or the wrist belt appears the breakdown; c)When current power more than 2.5 Soaks the foot at the same time, may use the bamboo carbon remote infrared ray waistband, Connect the waistband and the main engine, with belt fix waistband, turns on the infrared power switch, according to "MODE" the working pattern "L (low), M (center), H (high)" model, carries on the far infrared massage D、Attention 1 When the hand has water, do not insert or pulls out the power source, pays attention to the personal safety; 2 Avoid the hard object attacking and striking as far as possible, do not use the incisive thing to scratch delimits, avoid the machine surface to suffer injury; 3 When The machine surface has the dust, with the cleaning rag polishes , does not use the chemical agent; 4 The pressed key pays attention makes an effort evenly, by guarantees the instrument the normal use; 5 When use, must support the seat frame, and hold on the seat frame with the instrument connected place, to nearby two toward the external bracing, and straightens up to front ; when close the seat frame, uses the similar method to operate then.
|